Ultrasonic Flow Meters

20+ Years Manufacturing Experience

WM9100 Series Ultrasonic Water Meter DN350-DN600

Short Description:

WM9100 Series Bulk Water Meter Ultrasonic Water Meter is used for measuring, storage and display water flow.

Nominal Diameter: DN350-DN600


WM9100 Series Bulk Ultrasonic Water Meter is used for measuring, storage and display water flow.

Nominal Diameter: DN350-DN600

Features

feature-ico01

Full Bore Design, Without Pressure Loss.

feature-ico01

The Integrated Design Of Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement.

feature-ico01

Wide Range.

feature-ico01

Configured With Remote Data Collector, Remotely Connect To Smart Metering Platform.

feature-ico01

IP68 Protection Class, To Ensure Long Term Underwater Working.

feature-ico01
feature-ico01
feature-ico01
feature-ico01
feature-ico01
feature-ico01
feature-ico01

Low Consumption Design, Double D Size Batteries Can Continuously Work For 15 Years.

Bi-directional Measuring Forward And Reverse Flow.

Data Storage Function Can Save 10 Years' Data Including Day, Month And Year.

9 Digits Multi-line LCD Display.Can Display Cumulative Flow, Instantaneous Flow, Flow, Pressure, Temperature, Error Alarm, Flow Direction etc. At The Same Time.

Standard RS485 (Modbus) And OCT Pulse, A Variety Of Options, NB-IoT, GPRS, etc.

Stainless Steel 304 Pipe Which Is Tensile Molding Patent, Electrophoresis With Anti-scaling.

According To Sanitary Standard For Drinking Water.

Specificaitons

Max. Working Pressure

1.6Mpa

Temperature Class

T30, T50, T70, T90 (Default T30)

Accuracy Class

ISO4064, Accuracy Class 2

Body Material

Stainless Steel 304 (opt.SS316L)

Battery Life

15 Years (Consumption≤0.3mW)

Protection Class

IP68

Environmental Temperature

40℃~+70℃, ≤100%RH

Pressure Loss

△P10

Climatic And Mechanical Environment

Class O

Electromagnetic Class

E2

Communication

RS485 (baud rate is adjustable);Pulse, Opt. NB-IoT, GPRS

Display

9 digits multi-line LCD display.

Can display cumulative flow, instantaneous flow, flow rate, pressure, temperature, error alarm, flow direction etc. at the same time

RS485

Default baud rate 9600bps (opt.2400bps,4800bps), Modbus-RTU

Connection

Flanges according to EN1092-1 (others customized)

Flow Profile Sensitivity Class

U5/D3

Data Storage

Store the data, including day, month, and year for 10 years.The data can be permanently saved even powered off

Frequency

1-4 times/second

 

Measuring Range (R500)

Nominal Size

(mm)

350

400

500

600

(inch)

14

16

20

24

Overload Flow Q4 (m3/h)

2000

3125

5000

7875

Permanent Flow Q3 (m3/h)

1600

2500

4000

6300

Transitional Flow Q2 (m3/h)

5.12

8.00

12.80

20.16

Minimum Flow Q1 (m3/h)

3.20

5.00

8.00

12.60

R= Q3/Q1

500

Q2/Q1

1.6

 

Measuring Range (R400)

Nominal Size

(mm)

350

400

500

600

(inch)

14

16

20

24

Overload Flow Q4 (m3/h)

2000

3125

5000

7875

Permanent Flow Q3 (m3/h)

1600

2500

4000

6300

Transitional Flow Q2 (m3/h)

6.40

10.00

16.00

25.20

Minimum Flow Q1 (m3/h)

4.00

6.25

10.00

15.75

R= Q3/Q1

315

Q2/Q1

1.6

 

Measuring Range (R250)

Nominal Size

(mm)

350

400

500

600

(inch)

14

16

20

24

Overload Flow Q4 (m3/h)

2000

3125

5000

7875

Permanent Flow Q3 (m3/h)

1600

2500

4000

6300

Transitional Flow Q2 (m3/h)

6.40

10.00

16.00

25.20

Minimum Flow Q1 (m3/h)

4.00

6.25

10.00

15.75

R= Q3/Q1

315

Q2/Q1

1.6

 

Configuration Code

WM9100 WM9100 Ultrasonic Water Meter
  Pipe size
  350   DN350
  400   DN400
  ...     ...
  600   DN600
        Type
        A4    Full Bore Four-Channel (U5/D3)
              Power Supply
              1    Battery
              2    24VDC + Battery
                   Body Material
                   S    Stainless steel 304 (Standard)
                   H    Stainless steel 316
                         Pressure
                         1    0.6Mpa
                         2    1.0Mpa
                         3    1.6Mpa
                         4    2.5Mpa
                         O    Others
                               Connection
                               F    Flange
                                    Turn-down Ratio
                                    1    R500
                                    2    R400
                                    3    R250
                                         Output
                                          R    RS485 + OCT Pulse (Standard)
                                          O    Others
                                                Optional Function
                                                 N    None
                                                 1    Pressure Measurement
                                                 2    Built-in Remote Reading Function
                                                 3    Both ( 1 and 2 )

Dimension & Weight

2f220d30bb733e035873db0bb0842d5
a07f56361d6e9915a623e637babab84

Nominal Size

(mm)

350

400

500

600

(inch)

14

16

20

24

L-Length (mm)

500

600

600

800

B-Width (mm)

505

565

670

780

H-Height (mm)

593

648

743

853

h-height (mm)

245

275

328

378

D x n

22 x 16

26 x16

26 x 20

30 x 20

K (mm)

460

515

620

725

Pressure (MPa)

1.0

1.0

1.0

1.0

Weight (kg)

112

138

169

220

 

Remarks: Other length of pipe can be customized.