Ultrasonic Flow Meters

20+ Years Manufacturing Experience

TF1100-CH handheld transit time clamp on flow meter for fluid

Short Description:

TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.


TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Features

feature-ico01

14 hours battery (rechargeable), back-lit 4 lines display.

feature-ico01

Data logger function. 

feature-ico01

Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.

feature-ico01

Non-invasive transducers.

feature-ico01

Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

feature-ico01

Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

feature-ico01

Lightweight and easily transportable in box.

Specificaitons

Transmitter:

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V  Up to 14 h with fully charged internal batteries
Enclosure type Handheld
Degree of protection IP65 according to EN60529
Operating temperature -20℃ to +60℃
Housing material ABS( UL 94HB) 
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Communication OCT, RS232 ,Logged data
Security Keypad lockout, system lockout
Size 212*100*36mm
Weight 0.5kg

Transducer:

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size Type S    48(h)*28(w)*28(d)mm
Type M    60(h)*34(w)*33(d)mm
Type L     80(h)*40(w)*42(d)mm
Material of transducer Aluminum for standard temp. sensor, and peek for high temp. sensor
Cable Length Std: 5m

Configuration Code

TF1100-EH/CH   Handheld Transit-time Ultrasonic Flowmeter                
    Power supply                            
    A   85-265VAC                             
        Output Selection 1                        
        N   N/A                              
        1   OCT                              
        2   RS232 Output                           
        3   Data storage fuction                      
            Output Selection 2                    
                Same as above                    
                Output Selection 3                  
                    Transducer Type                
                    S   DN20-50                             
                    M   DN40-1000              
                    L   DN1000-6000            
                        Transducer Rail            
                        N   None            
                        RS   DN20-50             
                        RM   DN40-600  (For larger pipe size, pls contact us.)
                            Transducer temperature      
                            S   -3585 (for short periods up to 120℃))  
                            H   -35200℃((Only for S , M sensor.)
                                Pipeline Diameter     
                                DNX   e.g.DN50—50mm, DN4500—4500mm
                                    Cable length    
                                    5m   5m (standard 5m)   
                                    Xm   Common cable Max 300m(standard 5m) 
                                    XmH   High temp. cable Max 300m
                                             
TF1100-EH/CH A 1 2 /LTH— M N S DN100 5m   (example configuration)  

 