Application field-ultrasonic flow meter
Ultrasonic water meter has no moving parts, no blocking elements, is not affected by impurities in the water, and has a long service life. The output communication function is complete to meet various communication and wireless networking requirements. With excellent small flow detection ability,...Read more -
Ultrasonic water meter’s application effect
Ultrasonic water meter has the characteristics of high precision, good reliability, wide range ratio, long service life, no moving parts, no need to set parameters, arbitrary view installation and so on. Its working principle is very simple, it is a calculation method brought about by the speed c...Read more -
The features of ultrasonic heat meter
Ultrasonic heat meter has the following characteristics: 1. Non-contact measurement: Ultrasonic heat meter measures the temperature of the surface of the object through high frequency sound waves, without direct contact with the object, avoiding problems such as media pollution or device corrosio...Read more -
What to do in case of sensor failure given that the sensors are paired with the transmitter according to the calibration procedure ?
If one of paired sensor is failed and cannot be repaired, 1. to changed another new paired ( 2pcs) sensors. 2. to send the work normal sensor to our factory to pair another one. If the two sensors are not paired sensors, the meter can not work well and it will affect the meter accuracy. If the ...Read more -
The difference between TF1100-EH and TF1100-CH
TF1100-EH and TF1100-CH have the same menu and functions, the difference is TF1100-CH is Economical Type with cheaper price. Pls see attached picture, TF1100-EH is the green and TF1100-CH is the orange. TF1100-EH is with better material for main board, connectors,cable and case. TF1100-CH’s...Read more -
what does TF1100-CH includes?
The package includes: handheld transmitter x1pc M transducer x2pcs 5m transducer cable x2pcs SS belt x2pcs Charger x1pc Portable case x1pc The S and L transducer, datalogger, transducer rail, and couplant (grease)can be optional.Read more -
What compensation is available within the systems when there is not adequate straight run of pipe? Can this be compensated for?
Not adequate straight run of pipe is a common problem for all ultrasonic technology. It will affect the accuracy according to the shortage of straight pipe run.Read more -
With a poor measurement site environment in the plant and the voltage and power supplies fluctuating widely, is the instrument really able to keep running 24 hours a day repeatedly without stopping...
TF1100 is designed to work with high reliability under such conditions. It is provided with an intelligent signal conditioning circuit and internal correction circuitry. It will work under strong interference conditions and is able to adjust itself with strong or weak sound waves. It will work in...Read more -
New pipe, high quality material, and all installation requirements met: why still no signal detected?
Check pipe parameter settings, installation method and wiring connections. Confirm if the coupling compound is applied adequately, the pipe is full of liquid, transducer spacing agrees with the screen readings and the transducers are installed in the right direction.Read more -
Old pipe with heavy scale inside, no signal or poor signal detected: how can it be resolved?
Check if the pipe is full of fluid. Try the Z method for transducer installation (If the pipe is too close to a wall, or it is necessary to install the transducers on a vertical or inclined pipe with flow upwards instead of on a horizontal pipe). Carefully select a good pipe section and fully cl...Read more -
What factors will affect clamp on ultrasonic flow meter’s work ?
Compared with other types of ultrasonic flowmeters, the external clamp ultrasonic flowmeter has incomparable advantages. For example, the external clamp type ultra-side flowmeter can install the probe on the outer surface of the pipe, so that the flow is not broken and the flow is measured on the...Read more -
New version-TF1100 Series Transit Time Ultrasonic flow meters
We mainly updated below points for our transit time liquid flow measurement instruments. 1. Adopt more advanced DSP digital signal processing technology, dynamic zero is called correction technology, the instruments’ zero is smaller, better linear, more stable measurement. 2. Added the temperatur...Read more