Ultrasonic Flow Meters

20+ Years Manufacturing Experience

RS485 modbus and datalogger clamp on portable flow meter ultrasonic pure water flowmeter

Short Description:

The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

 

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.


The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Features

feature-ico01

50-hour battery (rechargeable), back-lit 4 lines display all integrated into a rugged, watertight enclosure.

feature-ico01

Data logger function. 

feature-ico01

The heat measurement function by configuring with paired temperature sensors.

feature-ico01

Non-invasive transducers.

feature-ico01

Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

feature-ico01

Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

feature-ico01

Lightweight and easily transportable in box.

Specificaitons

Transmitter:

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V Up to 50 hours with fully charged internal batteries
Enclosure type Portable
Degree of protection IP65
Operating temperature -20℃ to +60℃
Housing material ABS( UL 94HB) 
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy  unit GJ,KWh can be optional
Communication 4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS
Security Keypad lockout, system lockout
Size 270X215X175mm
Weight 3kg

Transducer:

Degree of protection

IP65 according to EN60529.(IP67 or IP68 Upon request)

Suited Liquid Temperature

Std. Temp.: -35℃~85℃ for short periods up to 120℃

High Temp.: -35℃~200℃ for short periods up to 250℃

Pipe diameter range

20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L

Transducer Size

Type S    48(h)*28(w)*28(d)mm

Type M    60(h)*34(w)*32(d)mm

Type L     80(h)*40(w)*42(d)mm  

Material of transducer

Aluminum for standard temp. sensor,and peek for high temp. sensor

Cable Length

Std:5m

Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type   Accuracy: ±0.1%

Configuration Code

TF1100-EP   Portable Transit-time Ultrasonic Flowmeter          
    Power supply                                
    A   85-265VAC                                 
        Output Selection 1                            
        N   N/A                                  
        1   4-20mA (accuracy 0.1%)                        
        2   OCT                                 
        3   RS232 Output                
        4   RS485 Output (ModBus-RTU Protocol)                               
        5   Data storage function            
        6   GPRS                          
            Output Selection 2                        
                Same as above                        
                Output Selection 3                      
                    Transducer Type                  
                    S   DN20-50                                 
                    M   DN40-1000                
                    L   DN1000-6000                
                        Transducer Rail                
                        N   None                
                        RS   DN20-50             
                        RM   DN40-600  (For larger pipe size, pls contact us.)
                            Transducer Temperature      
                            S   -3585 (for short periods up to 120)
                            H   -35200 (Only for S.M sensor.)  
                                Temperature Input Sensor    
                                N   None            
                                T   Clamp-on PT1000 ( DN20-1000 ) ( 0-200℃
                                    Pipeline Diameter     
                                    DNX   e.g.DN20—20mm, DN6000—6000mm
                                        Cable length    
                                        10m   5m (standard 5m) 
                                        Xm   Common cable Max 300m(standard 5m) 
                                        XmH High temp. cable Max 300m
TF1100-EP A 1 2 5 /LTP— M N S N DN100 5m   (example configuration)

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us: