Ultrasonic Flow Meters

20+ Years Manufacturing Experience

LMB Series Remote version ultrasonic level meter

Short Description:

LMB Series Remote version ultrasonic level meter is that the level meter’s electronic unit (set parameters, display, the signal output) is separate from the ultrasonic probe, connected by cable each other, the ultrasonic probe is installed in the upper container, the electronic unit (i.e., host) can choose the installation location flexibly, in order to facilitate observation, operation.

LMB series Remote ultrasonic level meter, the use of imported host shell, compact and easy to install, commonly functional, economical and practical is preferred.


1
2
4

LMB Series Remote version ultrasonic level meter is that the level meter's electronic unit (set parameters, display, the signal output) is separate from the ultrasonic probe, connected by cable each other, the ultrasonic probe is installed in the upper container, the electronic unit (i.e., host) can choose the installation location flexibly, in order to facilitate observation, operation.

LMB series Remote ultrasonic level meter, the use of imported host shell, compact and easy to install, commonly functional, economical and practical is preferred.

Features

feature-ico01

Separate probes are easy to install, host installation location is flexible and easy to operate.

feature-ico01

Ultrasonic probe using PVC or PTFE materials for a variety of corrosive conditions, sanitary type is optional.

feature-ico01

With the patents of Smart echo processing technology to ensure the accuracy and stability.

feature-ico01

Patented ultrasound probe structure with short blind range, high sensitivity, build-in with full range of automatic temperature compensation.

feature-ico01

Maximum length allowed for the probe cable 1000m, super anti-electromagnetic interference.

feature-ico01

6 relays at most, MODBUS, HART, PROFIBUS-DP protocol, and other functions.

feature-ico01

Electric heating probe for cold regions.

feature-ico01

Can be flexibly customized according to customer demand.

Technical Parameter

Model LMB
Measuring range (0~40m)based on different types of probes
Accuracy 0.2% Full span (In air)
Output Current DC4~20mA
Output Load 0~500Ω
Output Resolution 0.03% Full span
Mode of Indication 4 Digit LCD/6 Digit LED
Switching Output 2(high and low)(optional)
Relay Type 5A 250VAC/30VDC
Serial Communication RS485 ( Modbus ) ( optional )
Baud Rate 19200/9600/4800
Power Supply  DC21V~27V    0.1A
AC85~265V,0.05A
Temperature compensation The whole range is automatic
Temperature Range -40 ºC ~ +75 ºC
Measure Cycle 1.5second ( Tunable)
Parameter set up 3 induction buttons
Cable Fix PG13.5/PG11/
Crust Material ABS
Protection Grade IP67
Mode Installation Wall installation