Ultrasonic Flow Meters

20+ Years Manufacturing Experience

RC84 Series Ultrasonic Heat Meter DN50-600

Short Description:

RC82 Series ultrasonic heating (cooling, heating-cooling) meters are used for energy measurement of heating or chilled water. They are available in DN40-1000 and have an electronic energy calculator with separate register for heating and cooling energy. They are fitted with an M-Bus interface for integration into M-Bus networks.

RC82 Series ultrasonic heating (cooling, heating-cooling) meters are used for energy measurement of heating or chilled water. They are available in DN40-1000 and have an electronic energy calculator with separate register for heating and cooling energy. They are fitted with an M-Bus interface for integration into M-Bus networks.

Features

feature-ico01
Calculator can be hung at the body or installed separately. Distance apart could be up to 10 meter.
feature-ico01

Internal 3.6V high capacity lithium battery,external AC220V or DC24V optional

feature-ico01

Unique design for fluid structure to improve measuring accuracy and stability and reduce the requirement for straight piping during installation to up 5 and down 0.

feature-ico01

IP68 grade

feature-ico01

Can be mounted in flow pipe or in return pipe, and can be mounted in horizontal or vertical installation for different customer requirements.

feature-ico01

Complies CJ/188, GB/26831,MODBUS RTU and EN13757 communication protocol

feature-ico01

Support optical,RS485, wire and wireless M-Bus, short message, GPRS, pulse output interfaces, convenient for user to manage data in different manners.

feature-ico01

4~20 mA output optional.

feature-ico01

Complies with AGFW NOWA protocol.

Key Technology Points
  1. Up 5 down 0 straight piping installation
  2. More than 10 year shelf life
  3. Wireless transmission
  4. Pressure Loss Curve
RC84-1

Specification

Nominal diameter DN  (mm) 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000
Weight (kg) 8 9 12 15 17 20 30 45 75 100 130 150 190 350 500 600 750 950
Pressure loss (kPa/qp ) 4 6 9 11 7 6 4 4 4 2 2 2 2 2 2 2 2 2
Max flow rate qs (m3/h) 30 50 80 120 200 300 500 800 1200 1600 2000 2600 3200 4600 6000 8000 10000 12000
Nominal flow rate qp   (m3/h) 15 25 40 60 100 150 250 400 600 800 1000 1300 1600 2300 3000 4000 5000 6000
Nominal flow rate:Minimum flow rate
Qp/Qi
250:1,100:1 or 50:1 optional
Channel single or double channel optional single, double, three or four channels optional double, three or four channels optional
Flow rate maximum reading(m3) 9999999.9 m3 99999999 m3
Heat maximum reading( kW·h ) 99999999 kW·h 999999.99 MW·h
Accuracy class Class 2
Maximum working pressure 1.6MPa(2.5MPa, can be customized)
Heat(cooling) consumption calculation Start from 0.25K,can be customized
IP
grade
calculator IP67
Flow sensor IP68
Temperature range (4~130)℃
Temperature differential range (3~60)K((2~110)K ,can be customized)
Environmental Class Class A(5~55)℃or class B(-25~55)℃ or class C optional
Power supply 3.6V lithium battery(AC220V or DC24V, can be customized)
Battery lifetime ≥6years
Installation mode Horizontal or vertical
Heat(cooling)carrier Water
Temperature sensor PT1000(PT500、PT100 can be customized)

Dimension

Nominal Diameter
DN (mm)
50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000
L 200/270 200/300 225/300 250/360 350 350 350 400 450 500 550 600 650 750 875 1000 1230 1300
D 165 185 200 220 250 285 340 405 460 520 580 640 715 840 910 1025 1125 1255
H 247 258 279 299 388 418 476 535 589 645 699 756 819 931 1081 1166 1266 1381
K 125 145 160 180 210 240 295 355 410 470 525 585 650 770 840 960 1050 1170
n x φL 4 x φ18 4 x φ18 8 x φ18 8 x φ18 8 x φ18 8 x φ22 12 x φ22 12 x φ26 12 x φ26 16 x φ26 16 x φ30 20 x φ30 20 x φ33 20 x φ36 24 x φ36 24 x φ39 28 x φ39 28 x φ42

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us: