Ultrasonic Flow Meters

20+ Years Manufacturing Experience

new products

  • parshall flume open channel flow meter with 24VDC

    parshall flume open channel flow meter with 24VDC

    UOL serials is non-contact ultrasonic open channel flow meter, with low blind area, high sensitivity, high stability. It consists of ultrasonic probe and the host, mainly used for measuring water conservancy irrigation, sewage plants, enterprises and institutions of the flow rate of the sewage outfalls, urban sewage and chemical enterprise part of the flow measurement.

  • 14 hours battery clamp on handheld type ultrasonic flow meter

    14 hours battery clamp on handheld type ultrasonic flow meter

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Digital Output Handheld Flow Meter for fuel flow measurement

    Digital Output Handheld Flow Meter for fuel flow measurement

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • RS485 Modbus clamp on ultrasonic flow meter btu meter wall-mounted for pumps

    RS485 Modbus clamp on ultrasonic flow meter btu meter wall-mounted for pumps

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • data logger and RS485 modbus open channel flow meter velocity and level measurement

    data logger and RS485 modbus open channel flow meter velocity and level measurement

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

  • clamp-on doppler ultrasonic waste water flowmeter with 4-20mA output

    clamp-on doppler ultrasonic waste water flowmeter with 4-20mA output

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • Doppler pipe flow measurement clamp-on pipe flow viscous liquids and abrasives

    Doppler pipe flow measurement clamp-on pipe flow viscous liquids and abrasives

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • clamp-on digital 4-20mA output ultrasonic flowmeter

    clamp-on digital 4-20mA output ultrasonic flowmeter

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • 4-20mA output open channel and river measurement area velocity doppler flow meter monitor

    4-20mA output open channel and river measurement area velocity doppler flow meter monitor

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 Sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes. When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.
    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

  • DN40-DN4000 pipe doppler clamp on ultrasonic flow meter velocity display

    DN40-DN4000 pipe doppler clamp on ultrasonic flow meter velocity display

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • Portable Ultrasonic Doppler Flow Meter Clamp-on Flowmeter Flow Totalizer

    Portable Ultrasonic Doppler Flow Meter Clamp-on Flowmeter Flow Totalizer

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • Portable Water Flow Meter Ultrasonic Flow Meter

    Portable Water Flow Meter Ultrasonic Flow Meter

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Send your message to us: