Ultrasonic Flow Meters

20+ Years Manufacturing Experience

new products

  • datalogger water transit time clamp on ultrasonic flow meter liquid measurement

    datalogger water transit time clamp on ultrasonic flow meter liquid measurement

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • wall-mounted clamp on Doppler flowmeter raw water

    wall-mounted clamp on Doppler flowmeter raw water

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • ultrasonic water flow meter factory oem, odm flow measurement

    ultrasonic water flow meter factory oem, odm flow measurement

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Ultrasonic Flow Meter High Temperature Ultrasonic Flow Meter

    Ultrasonic Flow Meter High Temperature Ultrasonic Flow Meter

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • partially filled pipe doppler flow meter data logger output

    partially filled pipe doppler flow meter data logger output

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

  • Factory Sale Ultrasonic Flow Meter Ultrasonic Probe for Flowmeter

    Factory Sale Ultrasonic Flow Meter Ultrasonic Probe for Flowmeter

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • Dirty Liquids Measuring Meter Sewage Velocity Doppler Ultrasonic Flow Meter

    Dirty Liquids Measuring Meter Sewage Velocity Doppler Ultrasonic Flow Meter

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • wall mounted clamp on doppler ultrasonic liquid flowmeter for sewage water

    wall mounted clamp on doppler ultrasonic liquid flowmeter for sewage water

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • portable non invasive ultrasonic flow meter non contact sensors

    portable non invasive ultrasonic flow meter non contact sensors

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • excellent after-service wall mounted non invasive doppler ultrasonic liquid flow meter for dirty water

    excellent after-service wall mounted non invasive doppler ultrasonic liquid flow meter for dirty water

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • RS485 modbus and 4-20mA clamp on portable flow meter ultrasonic liquid flowmeter

    RS485 modbus and 4-20mA clamp on portable flow meter ultrasonic liquid flowmeter

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Fixed type open channel ultrasonic flow meter area velocity with RS485 modbus

    Fixed type open channel ultrasonic flow meter area velocity with RS485 modbus

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

Send your message to us: