Ultrasonic Flow Meters

20+ Years Manufacturing Experience

new products

  • waste water treatment partially filled pipe doppler flow meter

    waste water treatment partially filled pipe doppler flow meter

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

  • Wall mounted clamp on ultrasonic flow meter flowmter

    Wall mounted clamp on ultrasonic flow meter flowmter

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • high precision wastewater flow rate handheld ultrasonic flow meter

    high precision wastewater flow rate handheld ultrasonic flow meter

    Series DF6100-EH Doppler Handheld Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • wastewater flow rate measurement doppler ultrasonic flowmeter with 4-20mA

    wastewater flow rate measurement doppler ultrasonic flowmeter with 4-20mA

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • dn40-dn4000 sewage wastewater flow meter portable type

    dn40-dn4000 sewage wastewater flow meter portable type

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • 50mm effluent mechanical portable doppler water flow meter wastewater

    50mm effluent mechanical portable doppler water flow meter wastewater

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • battery operated handheld aluminum water ultasonic flow meter with rs232 outputs

    battery operated handheld aluminum water ultasonic flow meter with rs232 outputs

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • wall mounted 65mm insertion doppler flow meter for sewage water

    wall mounted 65mm insertion doppler flow meter for sewage water

    Series DF6100-EI Doppler Insertion Ultrasonic Flow Meter can measure metal or plastic pipes with a certain amount of air bubbles or suspended solids.

    Advanced technique allows this instrument to operate with high reliability and low maintenance. Insertion transducers permit the instrument to be installed without interrupting system pressure or flow.

  • Handheld Portable Ultrasonic Flow Meter For Industrial wastewater

    Handheld Portable Ultrasonic Flow Meter For Industrial wastewater

    Series DF6100-EH Doppler Handheld Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • wall mounted open channel flow meter with RS485 modbus

    wall mounted open channel flow meter with RS485 modbus

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

  • data storage transit time insertion ultrasonic water flow meter

    data storage transit time insertion ultrasonic water flow meter

    TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.

  • irrigation open channel ultrasonic flow meter with Pulse Output

    irrigation open channel ultrasonic flow meter with Pulse Output

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 Sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes. When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

Send your message to us: