Ultrasonic Flow Meters

20+ Years Manufacturing Experience

New product DN100 R500 stainless steel ultrasonic water meter

Short Description:

1. No moving part, Minimal flow instruction. Enduring accuracy.
2. Double channels ultrasonic transit-time sensor for High accuracy and reliable operation.
3. Can measure and storage both forward flow and backflow.
4. Active leak, theft, backflow, meter damage/tamper, rate of flow, and battery life indication
5. Above 15 years shelf life.
6. IP 68 design, longtime under water working.
7. Standard output is RS485, Lora, NB-IoT, 4-20mA, Pulse, GPRS can be optional.


Features

feature-ico01

No moving part, Minimal flow instruction. Enduring accuracy.

feature-ico01

Double channels ultrasonic transit-time sensor for High accuracy and reliable operation.

feature-ico01

Can measure and storage both forward flow and backflow. 

feature-ico01

Active leak, theft, backflow, meter damage/tamper, rate of flow, and battery life indication

feature-ico01

Above 15 years shelf life.

feature-ico01

IP 68 design, longtime under water working.

feature-ico01

Standard output is RS485, Lora, NB-IoT, 4-20mA, Pulse, GPRS can be optional.

Specificaitons

Types Ultrawater
Flow rate m³/h DN
50-2"
DN
65-2.5"
DN
80-3"
DN
100-4"
DN
150-6"
DN
200-8"
DN
250-10"
DN
300-12"
Q4 50 50 80 125 313 500 1250 1250
Q3 40 40 63 100 250 400 1000 1000
Q2 0.128 0.128 0.2 0.32 0.8 1.28 3.2 3.2
Q1 0.08 0.08 0.125 0.2 0.5 0.8 2 2
R=Q3/Q1 500 500 500 500 500 500 500 500
Max. Working Pressure 1.6Mpa
Pressure loss △P16
Temperature class T50
Work environment Temperature: -25℃~55℃, Humidity: ≤100%(RH)
Electromagnetic compatibility E2
Display 9-bit LCD display. Can display totalizer,  Instant flow,  error alarm,  flow direction, output
Data Storage Can storage the 10 years data, year, month and day
Output Modbus(baud rate:19200、9600、4800、2400); 4-20mA, Pulse,(default 2ml/pulse)
Power supply DC3.6V(disposable lithium batteries)   ≥ 15 years
Pipe Range DN50-DN300
IP Grade IP68
Accuracy class Class 1
Process connection Flange

Accuracy Curve

Ultrawater Serials Ultrasonic Water Meter2

Dimension

Ultrawater Serials Ultrasonic Water Meter4
Types Ultrawater
Nominal Diameter (mm) 50 65 80 100 150 200 250 300
(inch) 2 25 3 4 6 8 10 12
L- pipe length (mm) 200 200 225 250 300 350 449 499
B- width (mm) 165 185 200 220 285 340 406 489
H- height (mm) 194 210 210 223 282 332 383 456
h- height (mm) 40 90 90 103 140 165 203 245
Weight (mm) 9 11.5 13 15 32 45 68 96