Massive Selection for Water Flow Sensor - WM9100-ED Residential Ultrasonic Water Meter – Lanry Detail:
Description
Features
Technical Parameter
Residential ultrasonic water meter is used for measuring and display water flow.
Nominal Diameter: DN15~DN25
Product Features
With functions of self-diagnosis, flow sensor Alarm, Temperature Sensor Alarm, Over Range Alarm and battery under voltage alarm
With optic electric interface, hand-held infrared meter reading tool can read directly
Built-in wireless nb-iot
Stainless steel 316l is optional, meet the measurement of direct drinking water
Bi-directional measuring forward and reverse flow
According to sanitary standard for drinking water
Technical Parameter
Max. Working Pressure | 1.6Mpa |
Temperature Class | T30 |
Accuracy Class | ISO 4064, Accuracy Class 2 |
Body Material | Stainless SS304(opt. SS316L) |
Battery Life | 6 Years(Consumption≤0.3mW) |
Protection Class | IP68 |
Environmental Temperature | -40~+70℃,≤100%RH |
Pressure Loss | ΔP25(Based on different dynamic flow) |
Climatic And Mechanical Environment | Class O |
Electromagnetic Class | E2 |
Communication | Wired M-bus, RS485; Wireless LoRaWAN |
Display | 9 digits LCD display volume, flow rate, power alarm, flow direction, output etc. |
Connection | Thread |
Flow Profile Sensitivity Class | U5/D3 |
Data Storage | Store the latest 24 years’ data including day, month and year, The data can be permanently saved even powered off |
Frequency | 1-4 times/second |
Digital Display
Measuring Range and Dimensions(R250)
Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
15 | 2.5 | 0.016 | 0.010 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
20 | 4.0 | 0.026 | 0.016 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
25 | 6.3 | 0.040 | 0.025 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Measuring Range and Dimensions(R400)
Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
15 | 2.5 | 0.016 | 0.006 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
20 | 4.0 | 0.026 | 0.010 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
25 | 6.3 | 0.040 | 0.016 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Product detail pictures:
Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" would be the persistent conception of our corporation to the long-term to establish collectively with customers for mutual reciprocity and mutual benefit for Massive Selection for Water Flow Sensor - WM9100-ED Residential Ultrasonic Water Meter – Lanry, The product will supply to all over the world, such as: Brazil, Kuwait, Slovenia, Our products are produced with the best raw materials. Every moment, we constantly improve the production programme. In order to ensure better quality and service, we have been focusing on the production process. We have got high praise by partner. We are looking forward to establishing business relationship with you.
By Alva from Jakarta - 2017.08.15 12:36
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
By Elsa from New Zealand - 2017.04.18 16:45
Send your message to us:
Write your message here and send it to us