Ultrasonic Flow Meters

20+ Years Manufacturing Experience

MAG-11 Electromagnetic Flow Meter Thread Connection

Short Description:

Mag-11 Series Electromagnetic Flowmeter is based on the law of Farad Electromagnetic Induction, which is used to measure the conductance greater than 5 μS / cm volume of conductive liquids flow, such as such as water,sewage,mud,paper pulp,beverage,chemical,viscous liquid and suspension. Thread-type sensor breaks through the conventional design of electromagnetic flowmeter, it makes up the fatal flaw of some flow meters in the field of small flow measurement, it has the advantage of light and handy appearance,convenient installation,widely measuring range and hard to clogged, etc.


Mag-11 Series Electromagnetic Flowmeter is based on the law of Farad Electromagnetic Induction, which is used to measure the conductance greater than 5 μS / cm volume of conductive liquids flow, such as such as water,sewage,mud,paper pulp,beverage,chemical,viscous liquid and suspension. Thread-type sensor breaks through the conventional design of electromagnetic flowmeter, it makes up the fatal flaw of some flow meters in the field of small flow measurement, it has the advantage of light and handy appearance,convenient installation,widely measuring range and hard to clogged, etc.

Features

feature-ico01

No moving part and no pressure loss

feature-ico01

High accuracy of ±0.5% value of reading

feature-ico01

Can measure the tiny flow of 2L/h

feature-ico01

Measure forward and reverse direction flows.

feature-ico01

Many communication ways, such as GPRS, bluetooth wireless output, MODBUS and HART

feature-ico01

DN3-40pipes are available

feature-ico01

With the technology of stainless steel lining, can be used in the case of negative pressure

feature-ico01

Can measure the flow of various conductive liquids ( conductivity >5uS/cm)

Specification

Converter:

Display

4-line English LCD display,display the data of instantaneous flow,cumulative flow, heat (cold), the temperature of inlet and outlet water.

Current Output

4-20mA (can set flow or energy)

Pulse Output

Can choose full frequency or pulse equivalent output, the maximum frequency value of output is 5kHz.

Communication

RS485(MODBUS or BACNET), Data logger, Bluetooth

Power Supply

220VAC, 24VDC, 100-240VAC

Temperature

-20 ℃ ~ 60 ℃

Humidity

5% ~ 95%

Protection

IP65 (converter);  IP67, IP68 (sensor)

Structure

Compact or Remote

Sensor:

Diameter DN10 - DN40
Electrode Material SS316L, Hastelloy Alloy C
Lining Material FEP, PFA
Temperature 0 ~ 180℃
Protection Level IP65, IP67, IP68
Connection Thread-type
Pressure 1.0Mpa
Temperature sensor PT1000(optional)

Dimension

Diameter D L L1 L2 D1 L3 D3
DN10 G 3/4 B 110 50 15 R 1/4 28 13.5
DN15 R 1/2 30 20.4
DN20 G 1B 123 58 R 3/4 33 26.2
DN25 G 1 1/4B 128 60 18 R 1 35 33.2
DN32 G 1 3/4B 133 68 20 R 1 1/4 38 41.7
DN40

 

Electrode Material Selection

Material

Code

Performance of Corrosion Resistance

316L

V

Used in industrial water,domestic water,sewage,neutral solution and the weak acid such as carbonic acid and acetic acid.

Hastelloy Alloy C

Hc

Oxidation resistance acid,such as nitric acid ,mixed acid,complex acid mixed with sulfuric acid. Have good corrosion

resistance to seawater,alkali solution and chloride solution.

Inapplicable to:hydrochloric acid and Hydrofluoric acid

Hastelloy Alloy B

Hb

Has good corrosion resistance to non-oxidative acid,alkali,salt.

Inapplicable to: nitric acid.

Ti

Ti

Have good corrosion resistance to sea water,chloride,hypochlorite and various hydroxides.

Inapplicable to: reducing acids like hydrochloric acid,sulfuric acid,hydrofluoric acid.

Ta

Ta

Almost have the corrosion resistance to all chemical media,generally used for hydrochloric acid and sulfuric acid.

Inapplicable to:hydrofluoric acid,alkali and fuming sulfuric acid.

Tungsten Carbide

W

Have good wear resistance,used for the wearing media such as mud and paper pulp, but with poor corrosion resistance.

Platinum-iridium Alloy

Pt

Besides aqua acid and ammonium salt,almost have the corrosion resistance to all acid,alkali and salt solution.

 

Lining Material Selection

1. For high-temperature media (≥140℃),preference for PFA lining.

2. For the media with sanitation requirement should select FEP(or PTFE) lining

3. For the wearing media such as slurry and pulp should select PU or FEP lining.

4. For easy scaling media such as paper pulp, preference for FEP or PFA lining.

5. In the case of negative-pressure, should select FEP.

Material

Code

Performance of Corrosion Resistance

316L

V

Used in industrial water,domestic water,sewage,neutral solution and the weak acid such as carbonic acid and acetic acid.

Hastelloy Alloy C

Hc

Oxidation resistance acid,such as nitric acid ,mixed acid,complex acid mixed with sulfuric acid. Have good corrosion

resistance to seawater,alkali solution and chloride solution.

Inapplicable to:hydrochloric acid and Hydrofluoric acid

Hastelloy Alloy B

Hb

Has good corrosion resistance to non-oxidative acid,alkali,salt.

Inapplicable to: nitric acid.

Ti

Ti

Have good corrosion resistance to sea water,chloride,hypochlorite and various hydroxides.

Inapplicable to: reducing acids like hydrochloric acid,sulfuric acid,hydrofluoric acid.

Ta

Ta

Almost have the corrosion resistance to all chemical media,generally used for hydrochloric acid and sulfuric acid.

Inapplicable to:hydrofluoric acid,alkali and fuming sulfuric acid.

Tungsten Carbide

W

Have good wear resistance,used for the wearing media such as mud and paper pulp, but with poor corrosion resistance.

Platinum-iridium Alloy

Pt

Besides aqua acid and ammonium salt,almost have the corrosion resistance to all acid,alkali and salt solution.

 

Flow Measurement Range

Each of our electromagnetic flow meter has to be tested by strict actual calibration before leaving the factory. So when you select the measuring range, generally do not violate the precondition of "range must be larger than the measured flow", and it's better for the range close to the common measured flow. Generally make the common measured flow in the range of 50% to 80%.

The measuring range of Mag series electromagnetic flow-meter can be modified according to the actual situation.

The highest velocity can reach 12m/s.

Diameter(mm)(DN)                                     Scale Flow (m3/h)

10c

0.01

0.016

0.02

0.025

0.03

0.04

0.05

0.06

0.08

0.10

0.12

0.16

0.18

0.20

0.25

10b

0.03

0.04

0.05

0.06

0.07

0.08

0.1

0.12

0.16

0.2

0.3

0.4

0.5

0.6

0.7

10a

0.03

0.05

0.06

0.08

0.1

0.12

0.16

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1.0

10

0.1

0.16

0.2

0.25

0.3

0.4

0.5

0.6

0.8

1.0

1.2

1.6

2.0

2.5

2.8

15

0.2

0.4

0.5

0.6

0.8

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

6.3

20

0.4

0.6

0.8

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

11.3

25

0.6

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

17.7

32

0.9

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

20

25

28

40

1.4

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

20

25

30

40

45

50

2.1

4.0

5.0

6.0

8.0

10

12

16

20

25

30

40

50

60

70

65

4

6.0

8.0

10

12

16

20

25

30

40

50

60

80

100

120

80

6

10

12

16

20

25

30

40

50

60

80

100

120

160

180

100

8

16

20

25

30

40

50

60

80

100

120

160

200

250

280

125

13

25

30

40

50

60

80

100

120

160

200

250

300

400

440

150

19

40

50

60

80

100

120

160

200

250

300

400

500

600

630

200

34

60

80

100

120

160

200

250

300

400

500

600

800

1000

1100

250

53

100

120

160

200

250

300

400

500

600

800

1000

1200

1400

1600

300

76

160

200

250

300

400

500

600

800

1000

1200

1600

1800

2000

2500

350

100

200

250

300

400

500

600

800

1000

1200

1600

2000

2200

2500

3000

400

140

250

300

400

500

600

800

1000

1200

1600

2000

2500

2600

3000

4000

450

170

300

400

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

500

210

400

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

7000

600

310

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

6000

10000

700

420

700

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

6000

8000

13000

800

540

800

1000

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

18000

900

690

1000

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

12000

20000

1000

850

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

12000

16000

28000

1200

1220

2000

2500

3000

4000

5000

6000

8000

9000

10000

12000

16000

20000

26000

40000

1400

1660

2500

3000

4000

5000

6000

8000

10000

12000

16000

20000

25000

26000

30000

54000

1600

2160

3000

4000

5000

6000

8000

10000

12000

16000

20000

25000

30000

36000

40000

71000

1800

2740

5000

6000

7000

8000

10000

12000

16000

20000

25000

30000

36000

40000

45000

90000

2000

3380

6000

7000

8000

10000

12000

16000

2000

25000

30000

36000

40000

45000

50000

110000

Note 1 :   The Bold area is the flow we recommended.

Note 2 : The formula for the flow and velocity : V= 354 x F / D2     (V: Velocity, m/s, F: Flow, m3/h, D: Diameter, mm)


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us: