Ultrasonic Flow Meters

20+ Years Manufacturing Experience

MAG-11 Electromagnetic Flow Meter Flange Connection

Short Description:

Mag-11 Series Electromagnetic Flowmeter is based on the law of Farad Electromagnetic Induction, which is used to measure the conductance greater than 5 μS / cm volume of conductive liquids flow, such as such as water,sewage,mud,paper pulp,beverage,chemical,viscous liquid and suspension. Flange type sensor use the way of connecting the flange with pipe, has various types of electrode material and lining material. The sensor and converter can combined into the integrated electromagnetic flowmeter or split electromagnetic flowmeter.


Mag-11 Series Electromagnetic Flowmeter is based on the law of Farad Electromagnetic Induction, which is used to measure the conductance greater than 5 μS / cm volume of conductive liquids flow, such as such as water,sewage,mud,paper pulp,beverage,chemical,viscous liquid and suspension. Flange type sensor use the way of connecting the flange with pipe, has various types of electrode material and lining material. The sensor and converter can combined into the integrated electromagnetic flowmeter or split electromagnetic flowmeter.

Features

feature-ico01

Can measure the tiny flow of 2L/h

feature-ico01

Can select battery power and solar power

feature-ico01

Many communication ways, such as GPRS, bluetooth wireless output, MODBUS and HART

feature-ico01

With stable performance,good repeatability and high accuracy ( can reach 0.2% )

feature-ico01

No restricted baffle, no pressure loss,hard to clog,saving energy and reducing consumption

feature-ico01

DN10-2000 pipes are available.

feature-ico01

Can measure the flow of various conductive liquid ( conductivity: ≥5uS/cm)

feature-ico01

Measure the forward and reverse flow

Specification

Converter:

Display

4-line English LCD display,display the data of instantaneous flow,cumulative flow, heat (cold), the temperature of inlet and outlet water.

Current Output

4-20mA (can set flow or energy)

Pulse Output

Can choose full frequency or pulse equivalent output, the maximum frequency value of output is 5kHz.

Communication

RS485(MODBUS or BACNET), Data logger, Bluetooth

Power Supply

220VAC, 24VDC, 100-240VAC

Temperature

-20 ℃ ~ 60 ℃

Humidity

5% ~ 95%

Protection

IP65 (converter);  IP67, IP68 (sensor)

Structure

Compact or Remote

 

Sensor:

Application

All conductive liquid including water,beverage,various of corrosive media and liquid-solid two-phase fluid (mud,paper pulp).

Diameter

DN10-DN2000

Pressure

0.6 ~ 4.0 Mpa

Electrode Material

SS316L, Hc, Hb, Ti, Ta, W, Pt

Lining Material

Ne, PTFE, PU, FEP, PFA

Temperature

-40 ℃ ~ 80℃

Shell Material

Carbon Steel (Stainless Steel can be customized)

Protection Level

IP65, IP67, IP68

Connection

GB9119 (Can connect with HG20593-2009 flange directly),JIS,ANSI or customized.)

Temperature sensor

PT1000 (optional)

Lining Material & Pressure & Dimension & Weight

Pipe Diameter

Pressure (Mpa)

Lining Material

Dimension (mm)

Connection size

Weight (kg)

FEP

Ne

PU

PTFE

PFA

L

D

H

K

N x φ

DN10

4.0

O

 

 

 

O

150

95

142

60

4 x 14

3.5

DN15

O

 

O

O

O

65

DN20

O

 

O

O

O

105

147

75

4.5

DN25

O

 

O

O

O

115

152

85

DN32

O

 

O

O

O

140

172

100

4 x 18

6.5

DN40

O

 

O

O

O

150

177

110

7.0

DN50

O

O

O

O

O

200

165

205

125

9.5

DN65

O

O

O

O

O

185

216

145

8 x 18

12

DN80

O

O

O

O

O

200

228

160

15

DN100

1.6

O

O

O

O

O

250

220

258

180

17

DN125

O

O

O

O

O

250

284

210

21

DN150

O

O

O

O

O

300

285

315

240

8 x 22

28

DN200

1.0

O

O

O

O

O

350

340

366

295

36

DN250

O

O

O

O

O

400

395

420

350

12 x 22

49

DN300

O

O

O

O

O

450

445

470

400

61

 

Note:  O in the sheet means that different types of flow meters can choose different lining material.

When the working pressure of measured pipe is higher than pressure of sensor, the flow meter can be customized from our company.

The connection size in the sheet is designed according to GB/T9119-2010 standard,if you want the other connection size(such as ANSI/JIS ), can be customized from our company.

Measurement Range Selection

Scale Flow Selection

Each of our electromagnetic flow meter has to be tested by strict actual calibration before leaving the factory. So when you select the measuring range, generally do not violate the precondition of "range must be larger than the measured flow", and it's better for the range close to the common measured flow. Generally make the common measured flow in the range of 50% to 80%.

The measuring range of Mag series electromagnetic flow-meter can be modified according to the actual situation.

The highest velocity can reach 12m/s

Diameter(mm)(DN)                                                                                                    Scale Flow (m3/h)

10c

0.01

0.016

0.02

0.025

0.03

0.04

0.05

0.06

0.08

0.10

0.12

0.16

0.18

0.20

0.25

10b

0.03

0.04

0.05

0.06

0.07

0.08

0.1

0.12

0.16

0.2

0.3

0.4

0.5

0.6

0.7

10a

0.03

0.05

0.06

0.08

0.1

0.12

0.16

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1.0

10

0.1

0.16

0.2

0.25

0.3

0.4

0.5

0.6

0.8

1.0

1.2

1.6

2.0

2.5

2.8

15

0.2

0.4

0.5

0.6

0.8

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

6.3

20

0.4

0.6

0.8

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

11.3

25

0.6

1.0

1.2

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

17.7

32

0.9

1.6

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

20

25

28

40

1.4

2.5

3.0

4.0

5.0

6.0

8.0

10

12

16

20

25

30

40

45

50

2.1

4.0

5.0

6.0

8.0

10

12

16

20

25

30

40

50

60

70

65

4

6.0

8.0

10

12

16

20

25

30

40

50

60

80

100

120

80

6

10

12

16

20

25

30

40

50

60

80

100

120

160

180

100

8

16

20

25

30

40

50

60

80

100

120

160

200

250

280

125

13

25

30

40

50

60

80

100

120

160

200

250

300

400

440

150

19

40

50

60

80

100

120

160

200

250

300

400

500

600

630

200

34

60

80

100

120

160

200

250

300

400

500

600

800

1000

1100

250

53

100

120

160

200

250

300

400

500

600

800

1000

1200

1400

1600

300

76

160

200

250

300

400

500

600

800

1000

1200

1600

1800

2000

2500

350

100

200

250

300

400

500

600

800

1000

1200

1600

2000

2200

2500

3000

400

140

250

300

400

500

600

800

1000

1200

1600

2000

2500

2600

3000

4000

450

170

300

400

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

500

210

400

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

7000

600

310

500

600

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

6000

10000

700

420

700

800

1000

1200

1600

2000

2500

3000

3600

4000

5000

6000

8000

13000

800

540

800

1000

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

18000

900

690

1000

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

12000

20000

1000

850

1200

1600

2000

2500

3000

4000

5000

6000

7000

8000

10000

12000

16000

28000

1200

1220

2000

2500

3000

4000

5000

6000

8000

9000

10000

12000

16000

20000

26000

40000

1400

1660

2500

3000

4000

5000

6000

8000

10000

12000

16000

20000

25000

26000

30000

54000

1600

2160

3000

4000

5000

6000

8000

10000

12000

16000

20000

25000

30000

36000

40000

71000

1800

2740

5000

6000

7000

8000

10000

12000

16000

20000

25000

30000

36000

40000

45000

90000

2000

3380

6000

7000

8000

10000

12000

16000

2000

25000

30000

36000

40000

45000

50000

110000

Note 1 :   The Bold area is the flow we recommended.

Note 2 : The formula for the flow and velocity : V= 354 x F / D2     (V: Velocity, m/s, F: Flow, m3/h, D: Diameter, mm)

Electrode Material Selection

Material

Code

Performance of Corrosion Resistance

316L

V

Used in industrial water,domestic water,sewage,neutral solution and the weak acid such as carbonic acid and acetic acid.

Hastelloy Alloy C

Hc

Oxidation resistance acid,such as nitric acid ,mixed acid,complex acid mixed with sulfuric acid. Have good corrosion

resistance to seawater,alkali solution and chloride solution.

Inapplicable to:hydrochloric acid and Hydrofluoric acid

Hastelloy Alloy B

Hb

Has good corrosion resistance to non-oxidative acid,alkali,salt.

Inapplicable to: nitric acid.

Ti

Ti

Have good corrosion resistance to sea water,chloride,hypochlorite and various hydroxides.

Inapplicable to: reducing acids like hydrochloric acid,sulfuric acid,hydrofluoric acid.

Ta

Ta

Almost have the corrosion resistance to all chemical media,generally used for hydrochloric acid and sulfuric acid.

Inapplicable to:hydrofluoric acid,alkali and fuming sulfuric acid.

Tungsten Carbide

W

Have good wear resistance,used for the wearing media such as mud and paper pulp, but with poor corrosion resistance.

Platinum-iridium Alloy

Pt

Besides aqua acid and ammonium salt,almost have the corrosion resistance to all acid,alkali and salt solution.

 

Lining Material Selection

1. For high-temperature media (≥140℃),preference for PFA lining.

2. For the media with sanitation requirement should select FEP(or PTFE) lining.

3. For the wearing media such as slurry and pulp should select PU or FEP lining.

4. For easy scaling media such as paper pulp, preference for FEP or PFA lining.

5. In the case of negative-pressure, should select FEP.

Material Performance of Corrosion Resistance Working

Temperature

Applicable Range Diameter

(mm)

PTFE Almost have the corrosion resistance to all chemical media. -40 ~150℃ All media besides the fluid in negative-pressure pipe and also the fluid has the good wear resistance. DN15-1200
Ne Have the corrosion resistance to low consistence acid, alkali and salt, besides oil. -30~80℃ Industrial water,sewage,low consistence acid, alkali and salt solutions. DN50-2000
GFNE Have the corrosion resistance to low consistence acid, alkali and salt; have the resistance to high temperature and negative pressure. -25~160℃ Industrial water,sewage, hot water, low consistence acid, alkali and salt solutions. DN50-2000
PU Have good wear resistance,used for the wearing slurry, but with poor corrosion resistance. -30~80℃ Liquid containing solid grains(grout, slurry) DN15-400
FEP The corrosion resistance is equal to PTFE. -40 ~150℃ All fluid besides the wearing media such as mortar. DN3-400
PFA Have the corrosion resistance to all chemical media. The temperature resistance is better than FEP. -40~180℃ Same as PTFE, preference for sustained high temperature. DN3-400

 


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us: