Level transmitter is devided into the LVT series two-wire type and the LVR series digital type;
Features
Separate probes are easy to install, host installation location is flexible and easy to operate.
Convenient set parameters and read the data via Bluetooth/HART/MODBUS (Except the LVT 2-wire simple space output type)
Ultrasonic probe using PVC or PTFE materials for a variety of corrosive conditions, sanitary type is optional.
With the smart echo processing technology to ensure the accuracy and stability.
Patented ultrasound probe structure, ultra short blind range, high sensitivity, built-in full range of automatic temperature compensation.
Maximum length allowed for the probe cable 1000m, super anti-electromagnetic interference. ·
Electric heating probe for cold regions.
Can be flexibly customized according to customer demand.
Technical Parameter
Measuring range | LVT ( LVR) : 4.00m (Dead Zone: 0.20m) |
LVT ( LVR) : 6.00m (Dead Zone:0.25m) | |
LVT ( LVR) : 8.00m (Dead Zone:0.30m) | |
LVT ( LVR) : 12.00m (Dead Zone:0.50m) | |
LVT ( LVR) : 20.00m (Dead Zone:0.80m) | |
LVT ( LVR) : 30.00m (Dead Zone:1.20m) | |
LVT ( LVR) : 40.00m (Dead Zone:1.50m) | |
Effective rang of solid material level is 50% of liquid's | |
Accuracy | 0.2% Full span (In air) |
Temperature compensation | The whole range is automatic |
Temperature Range | -40 ºC ~75 ºC (LCD:-20 ºC ~+70ºC) |
Pressure Range | ±0.1MP (press definitely) |
Beam Angle | 8º(3db) |
Measure Cycle | 1.5 second (tunable) |
Cable Fix | PG13.5/M20/ ½NPT |
Cable | Ø 6-12mm |
Sensor Material | ABS/PVC/PTFE |
Protection Grade | IP68 |
Corrosion resistance | Resistant to strong corrosion |
Probe Cable Length | 10m(can be extended to 1000m by order) |
Installation in cold regions | Probe lengthened or choose electric heating |
Mode Installation | Thread/Flange/Frame |