TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges.
User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Features
14 hours battery (rechargeable), back-lit 4 lines display.
Data logger function.
Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
Non-invasive transducers.
Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.
Lightweight and easily transportable in box.
Specificaitons
Transmitter:
Measurement principle | Ultrasonic transit-time difference correlation principle |
Flow velocity range | 0.01 to 12 m/s, bi-directional |
Resolution | 0.25mm/s |
Repeatability | 0.2% of reading |
Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Response time | 0.5s |
Sensitivity | 0.003m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
Enclosure type | Handheld |
Degree of protection | IP65 according to EN60529 |
Operating temperature | -20℃ to +60℃ |
Housing material | ABS( UL 94HB) |
Display | 4 line×16 English letters LCD graphic display, backlit |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
Communication | RS232 , Logged data |
Security | Keypad lockout, system lockout |
Size | 212*100*36mm |
Weight | 0.5kg |
Transducer:
Degree of protection | IP65 according to EN60529.(IP67 or IP68 Upon request) |
Suited Liquid Temperature | Std. Temp.: -35℃~85℃ |
High Temp.: -35℃~200℃ | |
Pipe diameter range | 20-50mm for type S or B, 40-5000mm for type M or A |
Transducer Size | Type S 48(h)*28(w)*28(d)mm |
Type M 60(h)*34(w)*33(d)mm | |
Type B 40(h)*24(w)*22(d)mm | |
Type A 46(h)*31(w)*28(d)mm | |
Material of transducer | Aluminum for standard temp. sensor, and peek for high temp. sensor |
Cable Length | Std: 5m |
Configuration Code
TF1100-CH | Handheld Transit-Time Ultrasonic Flowmeter |
Power supply | |
A 85-265VAC | |
Output Selection 1 | |
N N/A | |
2 RS232 | |
3 Data Logger | |
Output Selection 2 | |
Same as above | |
Transducer Type | |
S DN20-50 -35~85℃ | |
M DN40-5000 -35~85℃ | |
B DN20-50 -35~200℃ | |
A DN40-5000 -35~200℃ | |
Transducer Rail | |
N N/A | |
RS DN20-50 | |
RM DN20-600 ( For larger pipe size, pls contact us ) | |
Pipeline Diameter | |
DNX e.g. DN20-20mm, DN500-5000mm | |
Cable Length | |
5m 5m (standard 5m) | |
Xm Common cable Max 300m (standard 5m) | |
XmH High temp. cable Max 300m |
TF1100-CH -A -2 /LTCH -A -N -DN100 -5m (example configuration)