Ultrasonic Flow Meters
20+ Years Manufacturing Experience
info@lanry-instruments.com
+86 21-67618991
Home
About
About Us
Factory
Exhibition
Products
Transit-time Ultrasonic Flowmeter
Wall-mounted Transit-time Ultrasonic Flowmeter TF1100-EC
Insertion Transit-time Ultrasonic Flowmeter TF1100-EI
Portable Transit-time Ultrasonic Flowmeter TF1100-EP
Handheld Transit-time Ultrasonic Flowmeter TF1100-CH
Wall Mounted Dual Channels Ultrasonic Flow Meter TF1100-DC
Insertion type Dual-channel Ultrasonic flowmeter TF1100-DI
Portable Dual Channels Ultrasonic Flow Meter TF1100-DP
Multi-channel Insertion Transit-time Ultrasonic Flowmeter TF1100-MI
Four-channel Insertion Transit-time Ultrasonic Flowmeter TF1100-FI
Doppler Ultrasonic Flowmeter
Wall-mounted Doppler Ultrasonic Flowmeter DF6100-EC
Insertion Doppler Ultrasonic Flowmeter DF6100-EI
Handheld Doppler Ultrasonic Flowmeter DF6100-EH
Portable Doppler Ultrasonic Flowmeter DF6100-EP
Partially Filled Pipe Flow Meter
Water Meter
Open Channel Flow Meter
Electromagnetic Flow Meter
Heat Meter
Level Meter
Working Principle
Transit-time ultrasonic flow meter working principle
Doppler ultrasonic flowmeter working principle
Area Velocity ultrasonic flow meter working principle
Application
TF1100 transit-time ultrasonic flow meter applications
DF6100 Doppler ultrasonic flowmeter applications
DOF6000 Doppler open channel ultrasonic flow meter applications
Support
Support
Videos
News
Contact
Download
Datasheets
English
Featured
OEM/ODM Manufacturer Ultrasound Flow Measurement - Handheld Transit-time Ultrasonic Flowmeter TF1100-EH&TF1100-CH – Lanry
Description Features Specificaitons Configuration Code TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. User can u...
inquiry
detail
Popular Design for Modbus Flow Meter - Portable Transit-time Ultrasonic Flowmeter TF1100-EP – Lanry
Description Features Specificaitons Configuration Code The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to ...
inquiry
detail
OEM/ODM China Multi Channel Ultrasonic Flowmeter - UOL Serials Open Channel flowmeter – Lanry
Description Features Specificaitons UOL serials is non-contact ultrasonic open channel flow meter, with low blind area, high sensitivity, high stability. It consists of ultrasonic probe and the host, mainly used for measuring water conservancy irrigation, sewage plants, enterprises and institutions of the flow rate of the sewage outfalls, urban sewage and chemical enterprise part of the flow measurement. Features Large screen display, double line 14 bit LCD liquid crystal display (wi...
inquiry
detail
Excellent quality Ultrasonic Flow Sensor - Wall-mounted Transit-time Ultrasonic Flowmeter TF1100-EC – Lanry
Description Features Specificaitons Configuration Code Applications TF1100-EC Wall-mounted Transit Time Ultrasonic Flow meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover t...
inquiry
detail
Hot sale Handheld Water Flow Meter - SC7 Serials Water Meter – Lanry
Features Key Technology Point Display Description Pressure Loss Curve Dimension Features Above 10 years shelf life. Installation at any angel, no influence for measurement accuracy. Ultrasonic signal quality detection. Photosensitive button, IP 68 design, longtime under water working. Support optical, RS485 and wired & wireless M-bus communication interfaces. Complies to MOD...
inquiry
detail
China OEM Flow Meter Pulse Output - Transit-Time Multi-channel Insertion Ultrasonic Flowmeter TF1100-MI – Lanry
Features Specificaitons Configuration Code Features 3.6V 76Ah battery power supply,with lifetime over 10 years (measuring cycle: 500ms). With storage function. Can storage both forward flow and backflow data 10 years (day, month, year ). Hot-tapped installation, no pipe line flow interrupted. Standard output is RS485 modbus, Pulse, NB-IoT, 4G, GPRS, GSM can be optional. Two channels and four channels can be optional...
inquiry
detail
OEM/ODM China Flow Meter For Sewage Water - SC7 Serials Water Meter – Lanry
Features Key Technology Point Display Description Pressure Loss Curve Dimension Features Above 10 years shelf life. Installation at any angel, no influence for measurement accuracy. Ultrasonic signal quality detection. Photosensitive button, IP 68 design, longtime under water working. Support optical, RS485 and wired & wireless M-bus communication interfaces. Complies to MOD...
inquiry
detail
Chinese Professional Doppler Water Flow Meter - Portable Doppler Ultrasonic Flowmeter DF6100-EP – Lanry
Description Features Specificaitons Configuration Code Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid. The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs Featur...
inquiry
detail
Chinese Professional Best Ultrasonic Flow Meters - Portable Transit-time Ultrasonic Flowmeter TF1100-EP – Lanry
Description Features Specificaitons Configuration Code The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to ...
inquiry
detail
Manufactur standard Portable Ultrasonic Water Flow Meter - SC7 Serials Water Meter – Lanry
Features Key Technology Point Display Description Pressure Loss Curve Dimension Features Above 10 years shelf life. Installation at any angel, no influence for measurement accuracy. Ultrasonic signal quality detection. Photosensitive button, IP 68 design, longtime under water working. Support optical, RS485 and wired & wireless M-bus communication interfaces. Complies to MOD...
inquiry
detail
Good quality Handheld Water Velocity Meter - Ultrawater Serials Ultrasonic Water Meter – Lanry
Features Specificaitons Accuracy Curve Dimension Features Active leak, theft, backflow, meter damage/tamper, rate of flow, and battery life indication Above 15 years shelf life. IP 68 design, longtime under water working. Standard output is RS485, Lora, NB-IoT, 4-20mA, Pulse, GPRS can be optional. Specificaitons Types Ultrawater Flow rate m³/h DN 50-2″ DN 65-2.5″ DN 80-3″ DN 10...
inquiry
detail
China OEM Wall Mounted Ultrasonic Flow Meter - Insertion Transit-time Ultrasonic Flowmeter TF1100-EI – Lanry
Description Features Specificaitons Configuration Code TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to opt...
inquiry
detail
<<
< Previous
132
133
134
135
136
137
138
Next >
>>
Page 135 / 341
Send your message to us: