Doppler wastewater flow transducers flow sensors clamp on ultrasonic flowmeter fixed

Short Description:

DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.


DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays, OCT outputs.

NOTES FOR APPLICATION
1. When installing ultrasonic transducers, it need enough straight pipe;
2. When straight pipe is not enough, by setting menu SERVICE, the flowmeter will still get high accuracy, and obtain a more accurate reading.
3. The measured liquid must contain a certain amount of air bubbles or suspended solids. When the liquid contains air bubbles too much or too big, the bubbles occupy a certain volume, and then lead to larger flowmeter reading. In this case, it needs to recalibrate the flowmeter.
4. When installing clamp-on doppler ultrasonic transducers, the pipe material should have a good acoustical conductivity;
5.  When the ultrasonic sensors / transducers need be installed underground, recommend the insertion type.

Features

feature-ico01

It is suitable for pipe sizes ranging from 40 to 4000mm

feature-ico01

For dirty liquids, a certain amount of air bubbles or suspended solids shall be contained

feature-ico01

Excellent low flow rate measurement ability, low to 0.05m/s

feature-ico01

A wide range of flow measurement, high flow rate can reach 12m/s

feature-ico01

High-temperature transducer is suitable to liquids of -35℃ ~ 200℃

feature-ico01

Do not need to shut down the pipe flow when installing the transducers

feature-ico01

User-friendly configuration

feature-ico01

4-20mA, Relay and OCT outputs

feature-ico01

Accuracy: 2.0% Calibrated span

Specificaitons

Transmitter:

Measurement principle Doppler ultrasonic
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy 0.5% -- 2.0% F.S.
Response time 2-60s for optional
Flow Velocity Range 0.05- 12 m/s
Liquid Types Supported Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.
Power Supply AC: 85-265V   DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Measurement Channels 1
Display 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable)
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Communication 4-20mA,Relay and OCT output
keypad 4pcs buttons
Size 244(h)*196(w)*114(d)mm
Weight 2.4kg

Transducer:

Transducers Type

Clamp-on

Degree of protection

IP65. IP67 or IP68 according to EN60529

Suited Liquid Temperature

Std. Temp.: -35℃~85℃ for short periods up to 120℃

High Temp.: -35℃~200℃ for short periods up to 250℃

Pipe diameter range

40-4000 mm

Transducer Size

60(h)*34(w)*32(d)mm

Material of transducer

Aluminum for standard temp.sensor and peek for high temp.sensor

Cable Length

Std: 10m 

Configuration Code

DF6100-EC   Wall-mounted Doppler Clamp-on Ultrasonic Flowmeter        
    Power supply                      
    A   110VAC                       
    B   220VAC                       
    D   24VDC                        
    S   65W Solar supply (including solar board)        
        Output Selection 1                  
        N   N/A                      
        1   4-20mA                      
        2   Relay                
        3   OCT                  
            Output Selection 2              
                Same as above            
                Sersor Type            
                S   Standard Clamp-on transducer (DN40-4000)         
                    Transducer Temperature      
                    S   -3585 (for short periods up to 120)
                    H   -35200
                        Pipeline Diameter     
                        DNX   e.g.DN40—40mm, DN4000—4000mm
                            Cable length    
                            10m   10m (standard 10m) 
                            Xm   Common cable Max 300m(standard 10m) 
                            XmH High temp. cable Max 300m
                                     
DF6100-EC B 1 N/LDC D S DN100 10m   (example configuration)