Our objective is to present premium quality products at aggressive prices, and top-notch services to buyers around the world. We have been ISO9001, CE, and GS certified and strictly adhere to their excellent specifications for Clamp On Ultrasonic Heat Meter, China Ultrasonic Water Flow Sensor, Clamp On Water Flow Sensor, Our organization has been devoting that "customer first" and committed to helping clients expand their small business, so that they become the Big Boss !
Chinese Professional Non Contact Flow Meters - clamp on portable transit time ultrasonic flow meter battery operated liquid flowmeter – Lanry Detail:


Description


Features


Specificaitons


Configuration Code

The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Features

feature-ico01

Non-invasive transducers.

feature-ico01

Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

feature-ico01

Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

feature-ico01

Lightweight and easily transportable in box.

Specificaitons

Transmitter:

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V Up to 50 hours with fully charged internal batteries
Enclosure type Portable
Degree of protection IP65
Operating temperature -20℃ to +60℃
Housing material ABS( UL 94HB)
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS
Security Keypad lockout, system lockout
Size 270X215X175mm
Weight 3kg

Transducer:

Degree of protection

IP65 according to EN60529.(IP67 or IP68 Upon request)

Suited Liquid Temperature

Std. Temp.: -35℃~85℃ for short periods up to 120℃

High Temp.: -35℃~200℃ for short periods up to 250℃

Pipe diameter range

20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L

Transducer Size

Type S    48(h)*28(w)*28(d)mm

Type M    60(h)*34(w)*32(d)mm

Type L     80(h)*40(w)*42(d)mm

Material of transducer

Aluminum for standard temp. sensor,and peek for high temp. sensor

Cable Length

Std:5m

Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type   Accuracy: ±0.1%

Configuration Code

TF1100-EP Portable Transit-time Ultrasonic Flowmeter
Power supply
A 85-265VAC
Output Selection 1
N N/A
1 4-20mA (accuracy 0.1%)
2 OCT
3 RS232 Output
4 RS485 Output (ModBus-RTU Protocol)
5 Data storage function
6 GPRS
Output Selection 2
Same as above
Output Selection 3
Transducer Type
S DN20-50
M DN40-1000
L DN1000-6000
Transducer Rail
N None
RS DN20-50
RM DN40-600  (For larger pipe size, pls contact us.)
Transducer Temperature
S -3585 (for short periods up to 120)
H -35200 (Only for S.M sensor.)
Temperature Input Sensor
N None
T Clamp-on PT1000 ( DN20-1000 ) ( 0-200℃
Pipeline Diameter
DNX e.g.DN20—20mm, DN6000—6000mm
Cable length
10m 5m (standard 5m)
Xm Common cable Max 300m(standard 5m) 
XmH High temp. cable Max 300m
TF1100-EP A 1 2 5 /LTP— M N S N DN100 5m (example configuration)


Product detail pictures:

Chinese Professional Non Contact Flow Meters - clamp on portable transit time ultrasonic flow meter battery operated liquid flowmeter – Lanry detail pictures


Related Product Guide:

We stick to our enterprise spirit of "Quality, Performance, Innovation and Integrity". We purpose to create a lot more price for our prospects with our rich resources, innovative machinery, experienced workers and great products and services for Chinese Professional Non Contact Flow Meters - clamp on portable transit time ultrasonic flow meter battery operated liquid flowmeter – Lanry, The product will supply to all over the world, such as: Poland, Poland, San Francisco, The design, processing, purchasing, inspection, storage, assembling process are all in scientific and effective documentary process , increasing usage level and reliability of our brand deeply, which makes us become superior supplier of the four major product categories shell castings domestically and obtained the customer's trust well.
  • The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Adela from Australia - 2018.06.18 19:26
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Mona from Denver - 2018.05.22 12:13

    Send your message to us:

    Write your message here and send it to us

    Send your message to us: