Best quality Flow Meters For Wastewater - WM9100-EV Prepaid Ultrasonic Water Meter – Lanry Detail:
Description
Features
Technical Parameter
WM9100-EV Residential Prepaid Ultrasonic Water Meter
Nominal Diameter: DN15~DN25
Product Features
With functions of self-diagnosis, flow sensor Alarm, Temperature Sensor Alarm, Over Range Alarm and battery under voltage alarm
With optic electric interface, hand-held infrared meter reading tool can read directly
Support swiping card to recharge and manage system remote valve control.
Low consumption design, battery can continuously work for 10 years
Bi-directional measuring forward and reverse flow
According to sanitary standard for drinking water
Technical Parameter
Max. Working Pressure | 1.6Mpa |
Temperature Class | T30 |
Accuracy Class | ISO 4064, Accuracy Class 2 |
Body Material | Stainless SS304(opt. SS316L) |
Battery Life | 10 Years(Consumption≤0.3mW) |
Protection Class | IP68 |
Environmental Temperature | -40~+70℃,≤100%RH |
Pressure Loss | ΔP25(Based on different dynamic flow) |
Climatic And Mechanical Environment | Class O |
Electromagnetic Class | E2 |
Communication | Wired M-bus, RS485; Wireless LoRaWAN |
Display | 9 digits LCD display volume, flow rate, power alarm, flow direction, output etc. |
Connection | Thread |
Flow Profile Sensitivity Class | U5/D3 |
Data Storage | Store the latest 24 years’ data including day, month and year, The data can be permanently saved even powered off |
Frequency | 1-4 times/second |
Digital Display
Measuring Range and Dimensions(R250)
Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
15 | 2.5 | 0.016 | 0.010 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
20 | 4.0 | 0.026 | 0.016 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
25 | 6.3 | 0.040 | 0.025 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Measuring Range and Dimensions(R400)
Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
15 | 2.5 | 0.016 | 0.006 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
20 | 4.0 | 0.026 | 0.010 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
25 | 6.3 | 0.040 | 0.016 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Product detail pictures:
Related Product Guide:
We also offer you product sourcing and flight consolidation expert services. We've our personal manufacturing unit and sourcing business. We can offer you virtually every variety of merchandise associated to our item range for Best quality Flow Meters For Wastewater - WM9100-EV Prepaid Ultrasonic Water Meter – Lanry, The product will supply to all over the world, such as: Italy, Montreal, Belarus, We believe in establishing healthy customer relationships and positive interaction for business. Close cooperation with our customers has helped us to create strong supply chains and reap benefits. Our products have gained us widespread acceptance and the satisfaction of our worldwide valued clients.
By Andrew Forrest from France - 2018.12.11 14:13
Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
By Mario from Ghana - 2017.05.02 11:33
Send your message to us:
Write your message here and send it to us